Tel: +86 574 87787718

E-mail: sales@risinginstru.com

1967 Multi-Port Block and Bleed Needle Valve

Contact Us

Details

Designation

Multi-Port Block and Bleed Needle Valve

Model

1967

Applications

Intended to isolate the pressure gauge from the measured fluid or to provide a means of throttling or dampening pressure pulsation. It allows additional instrument connections without adding permanent piping.

Pressure rating

10000psi

Operating Temperature

Max. 450℉ (+232℃)
Min. -65℉ (-54℃)

Flow Rate

Hard seat models Max.Cv=0.44

Handle

T type 304 stainless steel

Handle bolt

304 stainless steel

Dust cap

Plastic

Locking Nut

304 stainless steel

Packing bolt

316 stainless steel

Packing Gland

316 stainless steel

Packing washer

316 stainless steel

Packing

TEFLON as standard,viton for option

Bonnet

316 stainless steel

Valve stem

316 stainless steel, hard seat

Valve Body

316 stainless steel

Bleeding bolt

316 stainless steel at two sides, one is block, another is bleeding with smaller bleeding bolt

Stem seat

316 stainless steel, metal to metal sealing

Orifice size

0.236 inches (6mm)

Connection

1/2"NPT male x female

CONTACT WITH US
  • captcha

Copyright ©2018 Ningbo Rising Instrument Co.,Ltd. All Rights Reserved.